Rebecca Durante: Correct IUD Assessment Requires Evaluation of Both the Stem and Transverse Arms
Rebecca Durante, Midwife Trainee Sonographer at Chelsea and Westminster Hospital NHS, shared a post on LinkedIn:
“Think the IUD Is Normal?
Look Again with 3D Ultrasound
Correct IUD assessment requires evaluation of both the stem and transverse arms. While 2D ultrasound may suggest a normally positioned device, 3D coronal imaging can reveal subtle malposition.
In This Case
A 21-year-old nulliparous woman presented with persistent left lower quadrant pain since after IUD insertion (2 months ago).
2D Transvaginal Ultrasound
- IUD appears centrally located within the endometrial cavity.
3D Coronal View
- Misaligned IUD arms.
- Right arm extends 3 mm into the myometrium.
- Left arm extends into the uterine cornu.
These findings indicate a malpositioned IUD that is not apparent on 2D imaging.
Teaching Point: The 3D coronal view is the gold standard for assessing IUD arm position and detecting subtle embedment or malposition that may explain pelvic pain.”

Stay updated on all scientific advances in the field of fertility with Fertility News.
-
Nov 24, 2026, 19:43Evie Jeang: That’s a Wrap on F1 Weekend in Las Vegas
-
Nov 24, 2026, 19:30Kadhim Alabady: Chairing the 12th Global Summit on Gynecology, Fertility and Women’s Health
-
Nov 24, 2026, 19:18Rafael Trinchant Becomes an ESHRE-Certified Senior Clinical Embryologist
-
Nov 24, 2026, 19:06Stephen Parker Ellington: How Much Is Patient Dropout Costing Your Fertility Clinic?
-
Nov 24, 2026, 18:59Laura Rienzi: The Longer the Follow-up, the More Women Return for Their Frozen Eggs
-
Nov 24, 2026, 18:53Akram Kharbat: Fertility Science Has No Borders
-
Nov 24, 2026, 18:48Resa Nabor: To Every Woman Still Waiting for Her Miracle, Your Journey Matters
-
Nov 24, 2026, 18:33Fertilization Failure After ICSI: A Phenotype-First Framework for Biological Diagnosis
-
Nov 24, 2026, 17:42Peris Njoga-Kagotho: Who Bears the Responsibility When Assisted Reproduction Goes Wrong?